Overview | A Ceramic Filtration Primer | Manufacturing

Marathon Filters Testing History

DATE
DOCUMENTATION SOURCE
PATHOGENS
CHALLENGE
CONCENTRATION
FILTRATION
RESULTS

10/23/1995

University of Washington

Brevundimonas diminuta

1,000,000 organisms /ml

100% removal

3/1996

University of South Florida

Klebsiella terrigena
Cryptosporidium

31,000,000/ml
31,000/ml

Zero growth
100% removal

11/26/1997

University of Arizona
US EPA Guide Standard

Klebsiella terrigena
Cryptosporidia cysts

27,400,000,000/L
8,290,000/L

Zero growth
100% removal

1/30/1998

United States Marine Corps. Quantico, Virginia
(NSN 4610014495912)

Months of vigorous Tests during 1997

Tested 9 different brands of water filters for use of US Marine Corps.

* US Marine Corps. Selected MSR, Marathon Ceramics as the best one.

6/24/1998

Spectrum Labs, Inc. New Brighton, MN

Toxicological Extraction Evaluation

VOCs / EPA method number 502.2 scan

Meet requirements for compliance under NSF Number 42-1997

5/25/2000

Biovir Laboratories, Benicia, California

Klebsiella terrigena
Cryptosporidium parvum

170,000,000/100ml
110,000/L

Zero growth
100% removal

7/12/2000

Mountain Safety Research, WA, USA

E.coli, Raw sewage water

5,800,000/ml

100% removal

3/11/2002

Cascade Designs (CDI) Testing Lab. Seattle, WA, USA

Klebsiella terrigena

4,200,000/ml

100% removal

4/2/2002

CDI Testing Lab
Seattle, Washington

Klebsiella terrigena

9,400,000/ml

100% removal

5/15/2002

CDI Testing Lab
Seattle, WA, USA

Klebsiella terrigena

4,000,000/ml

100% removal

7/2/2002

University of Washington

E.coli
Heterotrophic bacteria

1,400,000/ml
67,400

Zero growth
None detected


Marathon Ceramics selected as One of the Top Ceramic Innovations In The Last 100 Years by the American Ceramic Society, May 1998.

*NSF Certified.(NSF 42-1997)