Overview
| A Ceramic Filtration Primer | Manufacturing
Marathon
Filters Testing History
|
|
DATE |
DOCUMENTATION SOURCE |
PATHOGENS |
CHALLENGE
CONCENTRATION |
FILTRATION
RESULTS |
|
10/23/1995 |
University
of Washington |
Brevundimonas
diminuta |
1,000,000
organisms /ml |
100%
removal |
|
3/1996 |
University
of South Florida |
Klebsiella
terrigena
Cryptosporidium |
31,000,000/ml
31,000/ml |
Zero
growth
100% removal |
|
11/26/1997 |
University
of Arizona
US EPA Guide Standard |
Klebsiella
terrigena
Cryptosporidia cysts |
27,400,000,000/L
8,290,000/L |
Zero
growth
100% removal |
|
1/30/1998 |
United
States Marine Corps. Quantico, Virginia
(NSN 4610014495912) |
Months
of vigorous Tests during 1997 |
Tested
9 different brands of water filters for use of US Marine Corps. |
*
US Marine Corps. Selected MSR, Marathon Ceramics as the best
one. |
|
6/24/1998 |
Spectrum
Labs, Inc. New Brighton, MN |
Toxicological
Extraction Evaluation |
VOCs
/ EPA method number 502.2 scan |
Meet
requirements for compliance under NSF Number 42-1997 |
|
5/25/2000 |
Biovir
Laboratories, Benicia, California |
Klebsiella
terrigena
Cryptosporidium parvum |
170,000,000/100ml
110,000/L |
Zero growth
100% removal |
|
7/12/2000 |
Mountain
Safety Research, WA, USA |
E.coli,
Raw sewage water |
5,800,000/ml |
100%
removal |
|
3/11/2002 |
Cascade
Designs (CDI) Testing Lab. Seattle, WA, USA |
Klebsiella
terrigena |
4,200,000/ml |
100%
removal |
|
4/2/2002 |
CDI
Testing Lab
Seattle, Washington |
Klebsiella
terrigena |
9,400,000/ml |
100%
removal |
|
5/15/2002 |
CDI
Testing Lab
Seattle, WA, USA |
Klebsiella
terrigena |
4,000,000/ml |
100%
removal |
|
7/2/2002 |
University
of Washington |
E.coli Heterotrophic bacteria |
1,400,000/ml 67,400 |
Zero
growth
None detected |
|
Marathon Ceramics selected as One of the Top
Ceramic Innovations In The Last 100 Years by the American
Ceramic Society, May 1998.
*NSF Certified.(NSF
42-1997) |

|